NTC inrush current limiter
In a circuit or a circuit which capacitor, filament,
heater or inverter / ballast for fluorescent lamp contains, the
Inrush current to be 10~100 times higher than normal operation.
This can be avoided by the use of an NTC thermistor which is connected in series.
is switched.
The larger cold resistance (zero power resistance) of the thermistor limits
thereby the inrush current when switching on.
After switching on, the flowing current leads to self-heating of the
thermistor, whereupon it reduces its resistance value to a very low ohmic value, allowing normal operating current.
-
D-5 series
CANCELLED
R25: 3Ω … 220Ω
Imax: 0.5A … 2.5A
∅5mm
Capacity at AC 240V 68μF
Capacity at AC 120V 272μF -
D-7 series
CANCELLED
R25: 1.3Ω … 220Ω
Imax: 0.8A … 4.5A
∅7mm
Capacity at AC 240V 130μF
Capacity at AC 120V 520μF -
D-9 series
CANCELLED
R25: 1Ω … 220Ω
Imax: 1.0A … 5.0A
∅9mm
Capacity at AC 240V 250μF
Capacity at AC 120V 1000μF -
D-11 series
CANCELLED
R25: 0.7Ω … 220Ω
Imax: 1.0A … 8.0A
∅11mm
Capacity at AC 240V 330μF
Capacity at AC 120V 1320μF -
D-13 series
CANCELLED
R25: 0.5Ω … 220Ω
Imax: 1.5A … 9.0A
∅13mm
Capacity at AC 240V 470μF
Capacity at AC 120V 1880μF -
D-15 series
CANCELLED
R25: 0.5Ω … 220Ω
Imax: 1.7A … 15.0A
∅15mm
Capacity at AC 240V 680μF
Capacity at AC 120V 2720μF -
D-20 series
CANCELLED
R25: 0.2Ω … 120Ω
Imax: 3.0A … 20.0A
∅20mm
Capacity at AC 240V 1200μF
Capacity at AC 120V 4800μF -
D-25 series
CANCELLED
R25: 0.2Ω … 33Ω
Imax: 4.0A … 20.0A
∅25mm
Capacity at AC 240V 1500μF
Capacity at AC 120V 6000μF -
D-30 series
CANCELLED
R25: 0.5Ω … 33Ω
Imax: 5.0A … 30.0A
∅30mm
Capacity at AC 240V 3500μF
Capacity at AC 120V 14000μF